Monitoring and CLI Changes
Monitoring and command-line changes when migrating from Apache Ignite 2 to GridGain 8, covering logs, metrics, system views, events, and the CLI tools.
This section covers changes to the monitoring stack (logs, metrics, system views, events) and to the command-line tools (control.sh, ignite.sh, sqlline, ignite-cdc.sh).
You can skip it if you have no monitoring, metrics, or log-parsing tooling and no operational scripts or automation to carry over.
Monitoring
Logs: the shipped Log4j config format differs,
IGNITE_QUIETdefaults tofalse(more verbose), and the log file-name pattern changed. Update log-parsing tooling.Metrics:
Ignite.metrics()and the newMetricRegistryAPI are unavailable. Use JMX orReadOnlyMetricRegistry.System views: several Ignite-only views (node attributes/metrics, baseline, SQL plan history, snapshot) are unavailable. Query the
SYSschema or use JMX.Events: event code 149 means different things in the two products, and several Ignite-only events (snapshot, consistency, SQL query execution) are unavailable. Update event listeners that filter by code.
CLI Changes
The command-line tools are mostly compatible, but several commands and mechanisms differ. See Control Script for the full control.sh reference.
control.sh
These control.sh commands, subcommands, and arguments changed:
--consistency
Use --cache partition_reconciliation.
--system-view
Use the SYS schema or JMX.
--performance-statistics
Not supported. Use JMX metrics or an external APM.
--cache subcommand
create
Removed. Define the cache in node configuration (XML), or create a table with SQL CREATE TABLE DDL.
metrics
Removed. Enable and read cache metrics over JMX (CacheMetricsMXBean) instead.
idle_verify_dump
Renamed. Call idle_verify --dump instead.
Argument
--ssl-factory
Not available.
--enable-experimental
Set the IGNITE_ENABLE_EXPERIMENTAL_COMMAND system property instead.
Changed command
--snapshot
An Apache Ignite 2 compatibility layer over GridGain snapshots, supporting the create, cancel, restore, and status actions. For the native tool, use snapshot-utility.sh.
Changed output
--state
Prints Cluster is active, Cluster is inactive, or Cluster is active (read-only) instead of Ignite's Cluster state: ACTIVE format. Update scripts that parse the output.
ignite.sh
Apache Ignite signals a successful restart by writing a file (RESTART_SUCCESS_FILE, set with -DIGNITE_SUCCESS_FILE); GridGain signals it with process exit code 250. Update custom restart wrappers to test for exit code 250 instead of the file. The JVM --add-opens set and the shipped Log4j2 configuration also differ.
sqlline
Pass custom JVM options in
SQL_JVM_OPTS. Apache Ignite usesJVM_OPTS.The command-history file location changed: Apache Ignite sets
--historyFileto~/.sqlline/ignite_history; GridGain leaves thesqllinedefault.
ignite-cdc.sh
Not available. GridGain has no CDC at all. For cross-cluster replication, use Data Center Replication; for other consumers, see the CDC entry in Features to Replace.
This page is: Copyright © 2026 MariaDB. All rights reserved.
Last updated
Was this helpful?

