Troubleshooting and Debugging
Common tips and techniques for debugging and troubleshooting GridGain and Ignite deployments, including persistence, thin clients, GC issues, and node recovery.
This article covers some common tips and tricks for debugging and troubleshooting GridGain and Ignite deployments.
Debugging Tools: Consistency Check Command
The ./control.sh|bat utility includes a set of consistency check commands that help with verifying internal data consistency invariants.
Persistence Files Disappear on Restart
On some systems, the default location for Ignite persistence files might be under a temp folder. This can lead to situations when persistence files are removed by an operating system whenever a node process is restarted. To avoid this:
Ensure that
WARNlogging level is enabled for GridGain. You will see a warning if the persistence files are written to the temporary directory.Change the location of all persistence files using the
DataStorageConfigurationAPIs, such assetStoragePath(...),setWalPath(...), andsetWalArchivePath(...)
Too Many Thin Clients Connect to Cluster
In some environments, the cluster may encounter a memory issue with an especially large number of clients. For example, if GridGain accepts a lot of client connections and then has to run a memory-intensive operation, the node may run out of memory. To avoid this:
Track the
client.connector.ActiveSessionsCountmetric to make sure you are not getting more connections than necessary.Use Java Metrics to keep track of memory usage on the node.
Increase the amount of direct memory by setting the
MaxDirectMemorySizeJVM parameter. Specific memory requirement heavily depends on the amount of clients and the load performed by them.
If the metrics show that you are running low on memory, use the thinClientProperty.maxConnectionsPerNode cluster property (or the maxConnectionsPerNode attribute of the ClientProcessorMXBean) to limit the number of thin client, JDBC, and ODBC connections per node.
Cluster Does Not Start After Field Type Changes
When developing your application, you may need to change the type of a custom object’s field. For instance, let’s say you have object A with field A.range of int type and then you decide to change the type of A.range to long right in the source code. When you do this, the cluster or the application will fail to restart because GridGain doesn't support field/column type changes.
You can use the experimental meta command to remove metadata that normally stores type affinity from the cluster. If you are not sure what to remove specifically, use the list subcommand to list all metadata types. You can specify the type to remove by ID or by name, and also specify the output folder to store a backup in. After you do so, GridGain will treat the column as a new type and continue to operate normally.
The meta command is not intended for normal cluster operation and the user is responsible for fulfilling conditions for proper execution:
Data of the removed type must not be stored in caches;
No other operations should be performed with the type. For example, you should not delete metadata while creating a new object.
You can also, in development, go into the file system and remove the following directories: marshaller/, db/, and wal/ located in the GridGain working directory (db and wal might be located in other places if you have redefined their location). This achieves a similar result to performing a meta command, but is less targeted.
In production, we still recommend adding a new field with a different name to your object model and removing the old one. This operation is fully supported. At the same time, the ALTER TABLE command can be used to add new columns or remove existing ones at run time.
Field Type Conflict Between Field Names That Differ in Case
Every binary field has a field ID that is calculated from the field name. The default ID mapper ignores case, so the data and DATA field names have the same field ID. Starting with GridGain 8.10, binary metadata is merged by field ID. The cluster rejects a field whose name differs from an existing field name only in case, if it has a different type. You may see one of the following errors:
BinaryObjectException: Wrong value has been set [typeName=..., fieldId=..., existingFieldName=data, fieldName=DATA, fieldType=String, assignedValueType=Timestamp]when a binary object is built.BinaryObjectException: Type '...' with typeId ... has a different/incorrect type for field 'DATA', which has the same field ID (...) as field 'data'. Expected 'String' but 'Timestamp' was provided.when the metadata is updated, for example by an SQLINSERTorUPDATE.IgniteSQLException: Cannot add column 'EXTRA' of type 'Timestamp': binary type '...' already has field 'extra' of type 'String' with the same field ID.when anALTER TABLE ... ADD COLUMNstatement runs.
The error message names both fields and their types. To fix the issue, change the data model:
Use one spelling of the field name everywhere: in the POJO, the binary object builder,
QueryEntity, and SQL.Give the new field a name that differs by more than case, or the same type as the existing field.
The type of an existing field cannot be changed. If you must reuse the field name with another type, back up the binary metadata folder of every node (<work dir>/db/binary_meta/<node folder> by default). Then delete the data that uses the old field type and remove the type metadata with the --meta remove command described above. Use the typeId from the error message.
As a temporary workaround, you can set the IGNITE_BINARY_METADATA_MERGE_BY_FIELD_ID_FEATURE system property to false on one of the cluster nodes (this requires a node restart). While any node has this property set to false, the whole cluster merges by field name, as in earlier versions.
Saving WAL Data to Disk on Corruption
The normal way to deal with data corruption is to use maintenance mode to resolve the corruption issue and return to normal operation. Sometimes it may lead to data being lost, for example when the index file is restored to a state not accounting for WAL. You can enable the IGNITE_DUMP_PERSISTENCE_FILES_ON_DATA_CORRUPTION system property to save all stored data to the db/dump/<consistentId> folder in the node work directory when corruption is detected.
Debugging GC Issues
The section contains information that may be helpful when you need to debug and troubleshoot issues related to Java heap usage or GC pauses.
Heap Dumps
You can configure JVM to dump the heap automatically when the OutOfMemoryException exception occurs. This helps if the root cause of this exception is not clear as the dump provides a deeper look at the heap state at the moment of failure:
Detailed GC Logs
In order to capture detailed information about GC related activities, make sure you have the settings below configured in the JVM settings of your cluster nodes:
Replace /path/to/gc/logs/ with an actual path on your file system.
For the G1 collector, the -Xlog:gc+ergo*=trace option provides many additional details that are purposefully not included in the basic GC log settings. Newer JDKs, such as Java 21, reject -XX:+PrintAdaptiveSizePolicy, and the JVM does not start.
Performance Analysis with Flight Recorder
In cases when you need to debug performance or memory issues you can use Java Flight Recorder to continuously collect low level runtime statistics, enabling after-the-fact incident analysis. To enable Java Flight Recorder use the following settings:
To start recording the state on a particular GridGain node use the following command:
For Flight Recorder related details refer to Oracle's official documentation.
JVM Pauses
Occasionally you may see an warning message about the JVM being paused for too long. It can happen during bulk loading, for example.
Adjusting the IGNITE_JVM_PAUSE_DETECTOR_THRESHOLD timeout setting may give the process time to finish without generating the warning. You can set the threshold via an environment variable, or pass it as a JVM argument (-DIGNITE_JVM_PAUSE_DETECTOR_THRESHOLD=5000) or as a parameter to ignite.sh (-J-DIGNITE_JVM_PAUSE_DETECTOR_THRESHOLD=5000).
The value is in milliseconds.
Client Node Fails to Start Before Server Node
When running environments where clusters need to be brought up often, the expected behavior is to start the server node first and then have client nodes connect to it. If done in reverse, it may cause issues as the server is still starting when the client tries to get data from it. You can manually provide a readiness check by creating an AtomicLong data structure on server node after it starts, and checking for it from the client nodes:
Here is an example of server-side code:
And the code below allows delays the client initialization until the value is retrieved:
Uneven Data Distribution
The default GridGain affinity function does not guarantee even data distribution. As a result, sometimes large clusters may encounter uneven data distribution across the nodes. For example, when a node leaves a 20-node cluster, some nodes may receive 10% of total cluster data, while others will not receive any additional data. This may cause performance issues with nodes that suddenly handle more data than expected.
In most cases, this can be remedied by increasing the number of partitions in your cluster. GridGain aims to reduce overhead caused by rebalancing data, so having smaller partitions means that data can be spread more evenly even in these scenarios.
If you are already in a situation of unfavorable data distribution, you can also force GridGain to redistribute data off the node by changing its consistent ID. This will trigger the rebalance process, usually resulting in a more fair distribution.
Error When Executing COPY FROM Command
The COPY FROM command uses Apache Parquet, which in turn uses Snappy for data compression. Snappy depends on native libraries that are typically extracted and executed from the /tmp directory. If the /tmp directory is mounted with the noexec option, the COPY FROM command will fail. Here is how the error may look like:
To resolve this issue, first verify the mount options for your /tmp directory. Then:
If possible, remount
/tmpwithout thenoexecoption.Alternatively, redirect native library extraction by setting the
org.xerial.snappy.tempdirsystem property. For example:-Dorg.xerial.snappy.tempdir=/mystorage/tmp.
Restoring Node with Generated Consistent ID
When a node goes down without a manually specified consistent ID and the node needs a restart with cleaned-up persistence folders, you cannot reintroduce it to the cluster without additional actions - the node will be introduced as a new node and require all operations for introducing a new node to the cluster.
As a workaround, you can reintroduce the new node with the consistent ID of the original node by specifying it manually in the node configuration. You must provide the consistent ID as a UUID object, not as a string value. Copy-pasting the UUID as a consistentId will not work.
The example below shows the correct way to configure a consistent ID for reintroduction:
See Also
This page is: Copyright © 2026 MariaDB. All rights reserved.
Last updated
Was this helpful?