Spring Boot Integration
Use GridGain 9 in a Spring Boot application through auto-configuration — Maven setup, client configuration, authentication, and SSL/TLS.
Overview
GridGain provides Spring Boot integration through auto-configuration, making it easy to use GridGain client in your Spring Boot applications. The integration automatically configures an IgniteClient bean that can be injected into your Spring components, allowing you to interact with the GridGain cluster using familiar Spring patterns.
Prerequisites
Java 17 or higher
Spring Boot 3.0 or higher
A running GridGain 9 cluster
Maven Configuration
To use GridGain with Spring Boot, add the following dependencies to your pom.xml:
<repositories>
<repository>
<id>GridGain External Repository</id>
<url>https://www.gridgainsystems.com/nexus/content/repositories/external</url>
</repository>
</repositories>
<dependencies>
<dependency>
<groupId>org.gridgain</groupId>
<artifactId>spring-boot-starter-ignite-client</artifactId>
<version>9.1.28</version>
</dependency>
</dependencies>The spring-boot-starter-ignite-client is a Spring Boot starter that includes all necessary dependencies and auto-configuration classes.
Basic Configuration
From Application Properties
The simplest way to configure GridGain in your Spring Boot application is through the application.properties file:
The auto-configuration will create an IgniteClient bean that connects to the specified address.
Using the Client
Once configured, you can inject the IgniteClient into your Spring components:
Configuration Properties
The Spring Boot integration supports all GridGain client configuration options through properties. All properties use the ignite.client prefix.
Connection Properties
ignite.client.addresses
String[]
Required. Addresses of GridGain cluster nodes. Can be a comma-separated list.
ignite.client.connectTimeout
Long
Connection timeout in milliseconds. Default value is 5000 ms.
ignite.client.heartbeatInterval
Long
Heartbeat message interval in milliseconds. Default value is 1000 ms.
ignite.client.heartbeatTimeout
Long
Heartbeat message timeout in milliseconds. Default value is 5000 ms.
ignite.client.backgroundReconnectInterval
Long
Background reconnect interval in milliseconds. Default value is 30000 ms.
ignite.client.operationTimeout
Long
Operation timeout in milliseconds. Default value is 0 (no timeout).
Example configuration with all connection properties:
Metrics Configuration
Enable client metrics to monitor connection statistics and performance:
When metrics are enabled, the client will expose metrics that can be monitored using standard Java monitoring tools like JMX or JDK Mission Control.
Authentication
Basic Authentication
If authentication is enabled on your GridGain cluster, you need to configure credentials. GridGain supports basic authentication with username and password.
Configuration File Approach
The simplest way to configure authentication is through properties:
Programmatic Approach
For more control, you can configure authentication programmatically using IgniteClientPropertiesCustomizer:
SSL/TLS Configuration
GridGain supports SSL/TLS encryption for client-server communication. Configure SSL through properties:
For detailed information on setting up SSL/TLS on the cluster side, see SSL/TLS documentation.
Setting Up Client
The example below shows how you can set up GridGain integration in your application:
This page is: Copyright © 2026 MariaDB. All rights reserved.
Last updated
Was this helpful?

