> For the complete documentation index, see [llms.txt](https://mariadb.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/cooperative-monitoring.md).

# Cooperative Monitoring

How several MaxScale instances monitoring the same cluster use server locks to decide which MariaDB Monitor is primary and allowed to change the cluster.

This page describes how MariaDB Monitors in several MaxScale instances share one cluster.

Cooperative monitoring means that multiple monitors (typically in different MaxScale instances) can monitor the same backend server cluster and agree on which one should be the primary monitor. Only the primary monitor can perform *switchover*, *failover*, *rejoin* and other cluster operations. The primary monitor also decides which server is the primary, i.e. target of write queries. Cooperative monitoring is enabled with the [cooperative\_monitoring\_locks](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#cooperative_monitoring_locks) -setting. This feature is meant to be used when multiple MaxScales manage the same replication cluster. It's useful even if [auto\_failover](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#auto_failover) and similar features are not in use, to ensure that all monitors agree on the primary server.

Cooperative monitoring uses [server locks](https://github.com/mariadb-corporation/mariadb-docs/tree/main/server/reference/sql-functions/secondary-functions/miscellaneous-functions/get_lock.md) for coordinating between monitors. When cooperating, the monitor regularly checks the status of a lock named *maxscale\_mariadbmonitor* on every server and acquires it if free. If the monitor acquires a majority of locks, it is the primary. If a monitor cannot claim lock majority, it is a secondary monitor. This means that multiple, or even all, monitors can be secondary if no monitor manages to claim lock majority.

The primary monitor of a cluster also acquires the lock *maxscale\_mariadbmonitor\_master* on the primary server. Secondary monitors check which server this lock is taken on and only accept that server as the writable primary. This arrangement is required so that multiple monitors can agree on which server is the primary regardless of replication topology. If a secondary monitor does not see the *master*-lock taken, then it won't consider any server writable, causing writes from that MaxScale to fail.

Lock majority means that a monitor has acquired a majority of locks across the servers, i.e. *n\_servers/2 + 1* (rounded down) locks. For example, a cluster of two servers needs two locks for majority, a cluster of three needs two, a cluster of four needs three, and a cluster of five needs three. [cooperative\_monitoring\_locks](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#cooperative_monitoring_locks) defines how the total number of available servers is calculated. `cooperative_monitoring_locks=majority_of_all` means that all configured servers, except for those in [servers\_no\_cooperative\_monitoring\_locks](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#servers_no_cooperative_monitoring_locks), add up to the total. This means that server status such as *Down* or *Maintenance* does not affect lock majority calculation. `cooperative_monitoring_locks=majority_of_running` means that only servers that are *Running* add up to the total. These options exist so that cooperative monitoring can adapt to different use cases. See [majority of running](#majority-of-running) and [majority of all](#majority-of-all) for suggested use-cases.

To check if a monitor is primary, fetch monitor diagnostics with `maxctrl show monitors` or the REST API. The boolean field **primary** indicates whether the monitor has lock majority on the cluster. If cooperative monitoring is disabled, the field value is *null*. Lock information for individual servers is listed in the server-specific field **lock\_held**. Again, *null* indicates that locks are not in use or the lock status is unknown.

If a MaxScale instance tries to acquire the locks but fails to get majority (perhaps another MaxScale was acquiring locks simultaneously) it will release any acquired locks and try again after a random number of monitor ticks. This prevents multiple MaxScales from fighting over the locks continuously as one MaxScale will eventually wait less time than the others. Conflict probability can be further decreased by configuring each monitor with a different `monitor_interval`.

The diagram below illustrates the lock handling logic.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
stateDiagram-v2
    accTitle: MaxScale cooperative monitoring — acquiring the primary lock majority
    accDescr {
        The MariaDB Monitor's cooperative-locking decision on each monitor tick. The monitor
        tick starts and checks lock status on all servers. If this MaxScale already has a
        majority of locks, it acquires any remaining free locks and continues as the primary
        MaxScale. If it does not have a majority, it checks whether it can get a majority. If it
        cannot, it continues as a secondary MaxScale. If it can, it acquires all free locks and
        rechecks whether it got a majority: if yes, it continues as the primary MaxScale; if no,
        it releases all acquired locks and continues as a secondary MaxScale.
    }
    [*] --> Secondary
    Secondary --> UpdateSec
    UpdateSec --> CheckLocks
    Primary --> UpdatePrim
    UpdatePrim --> CheckLocks

    CheckLocks --> GetRemaining: have majority
    CheckLocks --> CanGetMajority: majority available
    CheckLocks --> Secondary: majority unavailable

    GetRemaining --> Primary
    CanGetMajority --> Primary: got majority
    CanGetMajority --> Release: failed to get majority
    Release --> Secondary

    Primary: Primary monitor
    Secondary: Secondary monitor
    UpdatePrim: Update all servers
    UpdateSec: Update all servers
    CheckLocks: Check lock status
    GetRemaining: Acquire remaining locks
    CanGetMajority: Acquire free locks
    Release: Release acquired locks

    classDef proc fill:#fbe5d6,stroke:#c15911,stroke-width:2px,color:#111;
    classDef decision fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;

    class Primary,Secondary,UpdatePrim,UpdateSec,GetRemaining,Release proc
    class CheckLocks,CanGetMajority decision
```

*MariaDB Monitor cooperative locking: on each tick, a MaxScale that holds (or manages to acquire) a majority of server locks becomes primary; otherwise it releases any held locks and continues as secondary.*

## Majority of running

`cooperative_monitoring_locks=majority_of_running` is meant for situations where the network is reliable in the sense that a network partition is highly unlikely. In a reliable network, if a server becomes unconnectable for one MaxScale, it does so for all MaxScales. This is typically the case if all servers and all MaxScales are close by, in the same datacenter under the same router. Because `majority_of_running` adjusts the total number of servers in the majority calculation according to how many servers are connectable, a lock majority is possible even with just one server left running.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: Cooperative locking - majority with one server remaining (majority_of_running)
    accDescr {
        Three servers, Server 1, Server 2 and Server 3, and two MaxScales,
        MaxScale A and MaxScale B. Each MaxScale has an arrow to each server. The
        arrow from MaxScale A to Server 1 is labelled locked. The arrow from
        MaxScale B to Server 1 is labelled reachable. The four arrows from the two
        MaxScales to Server 2 and Server 3 are labelled unreachable. The boxes
        show the outcome: MaxScale A is primary, MaxScale B is secondary, Server 1
        is read-write, and Server 2 and Server 3 are down.
    }

    MXA["MaxScale A<br/>primary"]:::node
    MXB["MaxScale B<br/>secondary"]:::node
    S1["Server 1<br/>read-write"]:::node
    S2["Server 2<br/>down"]:::warn
    S3["Server 3<br/>down"]:::warn

    MXA ---> |locked| S1
    MXA -..-> |unreachable| S2 & S3
    MXB ---> |reachable| S1
    MXB -..-> |unreachable| S2 & S3

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    classDef warn fill:#fde2e2,stroke:#a12020,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*Both MaxScales maintain a connection to Server 1. All other servers are down. MaxScale A has claimed the exclusive lock on Server 1 and concludes it has lock majority (1/1 running servers). MaxScale A either considers Server 1 primary, or promotes it if* [*auto\_failover*](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#auto_failover) *is enabled. MaxScale A has also claimed the master-lock on Server 1. MaxScale B sees the locks taken and agrees that Server 1 is the primary.*

`cooperative_monitoring_locks=majority_of_running` should not be used when network partition is a credible threat. This is the case when the MaxScales and the servers are separated into multiple datacenters or are otherwise in multiple networks. If a network partition occurs, different MaxScales see different servers as connectable, and claim the exclusive locks on them. Thus, multiple MaxScales can conclude that they have lock majority, which leads to multiple primary servers. This may lead to write-queries being routed to multiple servers, splitting the cluster. Once the split happens, MaxScale can no longer reassemble the cluster automatically, and manual intervention is required.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: Cooperative locking - split-brain scenario (majority_of_running)
    accDescr {
        Two datacenters. Datacenter A holds Server 1, Server 2 and MaxScale A.
        Datacenter B holds Server 3, Server 4 and MaxScale B. Arrows labelled
        locked lead from MaxScale A to Server 1 and Server 2, and from MaxScale B
        to Server 3 and Server 4. Dotted arrows lead from each MaxScale to the two
        servers in the other datacenter. Dotted arrows show servers that the
        MaxScale cannot reach, as the page caption explains. The boxes show the
        outcome: MaxScale A and MaxScale B are both primary. Server 1 and Server 3
        are read-write, and Server 2 and Server 4 are read-only.
    }

    subgraph DCB["Datacenter B"]
      MXB["MaxScale B<br/>primary"]:::warn
      SB1["Server 3<br/>read-write"]:::node
      SB2["Server 4<br/>read-only"]:::node
    end
    subgraph DCA["Datacenter A"]
      MXA["MaxScale A<br/>primary"]:::warn
      SA1["Server 1<br/>read-write"]:::node
      SA2["Server 2<br/>read-only"]:::node
    end
    MXA --> |locked| SA1 & SA2
    MXB --> |locked| SB1 & SB2

    MXA -.-> SB1
    MXA -.-> SB2
    MXB -.-> SA1
    MXB -.-> SA2

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    classDef warn fill:#fde2e2,stroke:#a12020,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*The link between datacenters A and B is broken. MaxScale A holds locks on Server 1 and Server 2, but cannot connect to Server 3 and Server 4. Datacenter B has the opposite situation. Both MaxScales think they have two locks out of two running servers, and act as the primary MaxScale. This leads to a split-brain situation with two independent read-write servers.*

## Majority of all

`cooperative_monitoring_locks=majority_of_all` is meant for situations where a network partition is possible, e.g. when the servers and MaxScales are spread over multiple datacenters. Because `majority_of_all` calculates the required majority over all configured servers, it ensures that only one MaxScale can have lock majority at any time. This does not mean that the cluster will survive failure scenarios without service outage, though. If the network partitions or too many servers go down, then the typical outcome is that no MaxScale will have lock majority, no MaxScale is the primary MaxScale, and no server is writable. Still, this may be preferable to a split cluster with multiple primary servers.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: MaxScale cooperative locking - network partition (majority_of_all)
    accDescr {
        Three datacenters. Datacenter A holds Server 1 and MaxScale A, Datacenter
        B holds Server 2 and MaxScale B, and Datacenter C holds Server 3 and
        MaxScale C. Each MaxScale has an arrow labelled reachable to the server in
        its own datacenter, and dotted arrows to the servers in the other two
        datacenters. Dotted arrows show servers that the MaxScale cannot reach, as
        the page caption explains. The boxes show the outcome: all three MaxScales
        are secondary and all three servers are read-only.
    }

    subgraph DCC["Datacenter C"]
      MXC["MaxScale C<br/>secondary"]:::node
      SC1["Server 3<br/>read-only"]:::node
    end
    subgraph DCB["Datacenter B"]
      MXB["MaxScale B<br/>secondary"]:::node
      SB1["Server 2<br/>read-only"]:::node
    end
    subgraph DCA["Datacenter A"]
      MXA["MaxScale A<br/>secondary"]:::node
      SA1["Server 1<br/>read-only"]:::node
    end

    MXA --> |reachable| SA1
    MXA -.-> SB1
    MXA -.-> SC1

    MXB --> |reachable| SB1
    MXB -.-> SA1
    MXB -.-> SC1

    MXC --> |reachable| SC1
    MXC -.-> SA1
    MXC -.-> SB1

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    classDef warn fill:#fde2e2,stroke:#a12020,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*The link between datacenters A, B and C is broken. Each MaxScale can only connect to the server in their local datacenter. Each MaxScale can acquire one lock out of three total servers, which is not enough for majority. All MaxScales are in secondary status, and will release any locks they may have acquired. No primary server is detected so all servers are in read-only mode. Once connectivity is restored, one MaxScale will again claim lock majority and the cluster resumes normal operation.*

The downside of `majority_of_all` is that it can lead to a read-only cluster in situations where it is not strictly necessary. This is the case when too many servers go down or otherwise become unconnectable, so that a majority can no longer be formed.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: MaxScale cooperative locking - no majority (majority_of_all)
    accDescr {
        Four servers, Server 1, Server 2, Server 3 and Server 4, and two
        MaxScales, MaxScale A and MaxScale B. Arrows labelled reachable lead from
        each MaxScale to Server 1 and Server 2. Dotted arrows lead from each
        MaxScale to Server 3 and Server 4. Dotted arrows show servers that the
        MaxScale cannot reach, as the page caption explains. The boxes show the
        outcome: both MaxScales are secondary, Server 1 and Server 2 are
        read-only, and Server 3 and Server 4 are down.
    }

    MXA["MaxScale A<br/>secondary"]:::node
    MXB["MaxScale B<br/>secondary"]:::node
    S1["Server 1<br/>read-only<br/>"]:::node
    S2["Server 2<br/>read-only<br/>"]:::node
    S3["Server 3<br/>down"]:::warn
    S4["Server 4<br/>down"]:::warn

    MXA --> |reachable| S1 & S2
    MXB --> |reachable| S1 & S2
    MXA -.-> S3 & S4
    MXB -.-> S3 & S4

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    classDef warn fill:#fde2e2,stroke:#a12020,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*Both MaxScales maintain a connection to Server 1 and Server 2. Server 3 and Server 4 are down. Neither MaxScale can reach lock majority, which would require three locks. Servers remain unlocked. Because both MaxScales are in secondary mode, no server is declared primary. Servers 1 and 2 are in read-only mode.*

`cooperative_monitoring_locks=majority_of_all` requires at least three servers to work reliably. With only two servers, just one server going down means that lock majority is no longer possible (one out of two is not a majority). Also, separating the three servers to just two datacenters is fragile: if the datacenter with two servers loses power, the remaining datacenter can no longer reach majority.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: MaxScale cooperative locking - majority datacenter down (majority_of_all)
    accDescr {
        Two datacenters. Datacenter A holds Server 1 and MaxScale A. Datacenter B
        holds Server 2, Server 3 and MaxScale B. An arrow labelled reachable leads
        from MaxScale A to Server 1, and dotted arrows lead from MaxScale A to
        Server 2 and Server 3. Dotted arrows show servers that the MaxScale cannot
        reach, as the page caption explains. MaxScale B has no arrows. The boxes
        show the outcome: MaxScale B, Server 2 and Server 3 are down. MaxScale A
        is secondary and Server 1 is read-only.
    }

    subgraph DCB["Datacenter B"]
      MXB["MaxScale B<br/>down"]:::warn
      SB1["Server 2<br/>down<br/>"]:::warn
      SB2["Server 3<br/>down<br/>"]:::warn
    end
    subgraph DCA["Datacenter A"]
      MXA["MaxScale A<br/>secondary"]:::node
      SA1["Server 1<br/>read-only<br/>"]:::node
    end

    MXA --> |reachable| SA1
    MXA -.-> SB1
    MXA -.-> SB2

    MXB ~~~ SB1
    MXB ~~~ SB2

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    classDef warn fill:#fde2e2,stroke:#a12020,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*Datacenter B is down. Since it contained two out of three servers, the surviving datacenter does not have enough servers to claim majority.*

Resistance to datacenter-wide failures requires at least three datacenters, so that a majority can be formed with the remaining datacenters.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: MaxScale cooperative locking - one datacenter down (majority_of_all)
    accDescr {
        Three datacenters. Datacenter A holds Server 1 and MaxScale A, Datacenter
        B holds Server 2 and MaxScale B, and Datacenter C holds Server 3 and
        MaxScale C. Arrows labelled locked lead from MaxScale A to Server 1 and
        Server 2. Arrows labelled reachable lead from MaxScale B to Server 1 and
        Server 2. Dotted arrows lead from MaxScale A and MaxScale B to Server 3.
        Dotted arrows show servers that the MaxScale cannot reach, as the page
        caption explains. MaxScale C has no arrows. The boxes show the outcome:
        MaxScale C and Server 3 are down. MaxScale A is primary and Server 1 is
        read-write. MaxScale B is secondary and Server 2 is read-only.
    }
    subgraph DCC["Datacenter C"]
      MXC["MaxScale C<br/>down"]:::warn
      SC1["Server 3<br/>down"]:::warn
    end
    subgraph DCB["Datacenter B"]
      MXB["MaxScale B<br/>secondary"]:::node
      SB1["Server 2<br/>read-only"]:::node
    end
    subgraph DCA["Datacenter A"]
      MXA["MaxScale A<br/>primary"]:::node
      SA1["Server 1<br/>read-write"]:::node
    end

    MXA --> |locked| SA1
    MXA --> |locked| SB1
    MXA -.-> SC1

    MXB --> |reachable| SA1
    MXB --> |reachable| SB1
    MXB -.-> SC1

    MXC ~~~ SC1

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    classDef warn fill:#fde2e2,stroke:#a12020,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*Datacenter C is down. It only contained one out of three servers, so the servers in the remaining datacenters can still form a majority.*

If a setup with just two datacenters needs to survive a datacenter failure, and also be resistant to a split-brain scenario, then neither `cooperative_monitoring_locks` mode is sufficient. Such a situation requires an outside orchestrator to manage the [passive](https://mariadb.com/docs/maxscale/maxscale-management/deployment/installation-and-configuration/maxscale-configuration-guide/global-settings.md#passive) -state of the MaxScales. Both MaxScale and servers also need to be carefully configured so that different MaxScales cannot select different primaries. See [failover with multiple MaxScales](https://mariadb.com/docs/maxscale/mariadb-maxscale-tutorials/failover-with-multiple-maxscales.md) for more information.

Cooperative monitoring only deals with MaxScale-to-MaxScale synchronization i.e. that all MaxScales eventually select the same primary server and that only one MaxScale alters the cluster. Cooperative monitoring does NOT ensure transaction consistency. If the primary MaxScale loses connection to the current primary server, other MaxScales may still see that server as the primary for some time and commit transactions. Only once the *maxscale\_mariadbmonitor\_master*-lock expires (8s with default monitor settings), do the other MaxScales realize that the situation has changed. During this time, transactions can still commit to the old primary.

```mermaid
%%{init: {"themeVariables": {"edgeLabelBackground": "#eef2ff"}}}%%
flowchart TD
    accTitle: MaxScale cooperative locking - one datacenter with primary server disconnected (majority_of_all)
    accDescr {
      Three datacenters. Datacenter A holds Server 1 (read-write, soon read-only) and MaxScale A
      (secondary). Datacenter B holds Server 2 (read-only, soon read-write) and MaxScale B
      (primary). Datacenter C holds Server 3 (read-only) and MaxScale C (secondary). Datacenter
      A has lost its connection to datacenters B and C but keeps running. MaxScale A still
      reaches Server 1, the now-stale primary, while MaxScale B holds the locks on Server 2 and
      Server 3, and MaxScale C reaches Server 3 normally and also has an unlabelled arrow to
      Server 2. Until the master lock expires, Server 1 keeps accepting writes while MaxScale B
      promotes Server 2, so the two servers diverge.
    }
    subgraph DCC["Datacenter C"]
      MXC["MaxScale C<br/>secondary"]:::node
      SC1["Server 3<br/>read-only"]:::node
    end
    subgraph DCB["Datacenter B"]
      MXB["MaxScale B<br/>primary"]:::node
      SB1["Server 2<br/>read-only,<br/>soon read-write"]:::node
    end
    subgraph DCA["Datacenter A"]
      MXA["MaxScale A<br/>secondary"]:::node
      SA1["Server 1<br/>read-write,<br/>soon read-only"]:::node
    end

    MXA --> |reachable| SA1
    MXA -.-> SB1
    MXA -.-> SC1

    MXB -.-> SA1
    MXB --> |locked| SB1
    MXB --> |locked| SC1

    MXC -.-> SA1
    MXC --> SB1
    MXC --> |reachable| SC1

    classDef node fill:#e2f0f2,stroke:#0a5a6b,stroke-width:2px,color:#111;
    linkStyle default color:#111111
```

*Datacenter A disconnects from datacenters B and C but stays running. MaxScale A (secondary) still sees the master-lock taken on Server 1 and assumes that it is the primary. After a few seconds, the lock expires, and MaxScale A labels the server read-only. However, many transactions could have committed during this time. MaxScale B operates independently, and promotes Server 2. Server 1 and Server 2 will then diverge.*

This situation cannot be entirely protected against. The best remedy is to use [semisynchronous replication](https://mariadb.com/docs/server/ha-and-performance/standard-replication/semisynchronous-replication.md)) with a sufficiently long (e.g. 1 minute) [rpl\_semi\_sync\_master\_timeout](https://mariadb.com/docs/server/ha-and-performance/standard-replication/semisynchronous-replication.md#rpl_semi_sync_master_timeout). This way, when Server 1 loses connectivity to the other servers, writes to Server 1 will stall, greatly limiting the number of transactions that may be committed. Any transactions in flight will eventually commit, though. As of MaxScale 23.02.19, 23.08.15 and 24.02.11, 25.01.8 and 25.10.4, if a secondary MaxScale is configured with `cooperative_monitoring_locks=majority_of_all` and it notices that the primary server has lost the *master*-lock, MaxScale will disconnect the entire routing session. Thus, clients will not get an OK-reply to their hanging commits, alerting them that something is wrong.

## Related settings

Use [servers\_no\_cooperative\_monitoring\_locks](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#servers_no_cooperative_monitoring_locks) to define servers that do not take part in cooperative monitoring.

Use [cooperative\_monitoring\_arbitrator\_nodes](https://mariadb.com/docs/maxscale/reference/maxscale-monitors/mariadb-monitor/mariadb-monitor-settings.md#cooperative_monitoring_arbitrator_nodes) to define servers that only take part in cooperative monitoring.

## Releasing locks

Monitor cooperation depends on the server locks. The locks are connection-specific. The owning connection can manually release a lock, allowing another connection to claim it. Also, if the owning connection closes, the MariaDB Server process releases the lock. How quickly a lost connection is detected affects how quickly the primary monitor status moves from one monitor and MaxScale to another.

If the primary MaxScale or its monitor is stopped normally, the monitor connections are properly closed, releasing the locks. This allows the secondary MaxScale to quickly claim the locks. However, if the primary simply vanishes (broken network), the connection may just look idle. In this case, the MariaDB Server may take a long time before it considers the monitor connection lost. This time ultimately depends on TCP keepalive settings on the machines running MariaDB Server.

The TCP keepalive settings can be configured for just the server process. See [Server System Variables](https://github.com/mariadb-corporation/mariadb-docs/tree/main/server/ha-and-performance/optimization-and-tuning/system-variables/server-system-variables.md#tcp_keepalive_interval) for information on settings *tcp\_keepalive\_interval*, *tcp\_keepalive\_probes* and *tcp\_keepalive\_time*. These settings can also be set on the operating system level, as described [here](https://www.tldp.org/HOWTO/TCP-Keepalive-HOWTO/usingkeepalive.html).

As of MaxScale 22.08.13, 23.02.10, 23.08.6 and 24.02.2, configuring TCP keepalive is no longer necessary as the monitor sets the session *wait\_timeout* variable when acquiring a lock. This causes the MariaDB Server to close the monitor connection if the connection appears idle for too long. The value of *wait\_timeout* used depends on the monitor interval and connection timeout settings, and is logged at MaxScale startup.

A monitor can also be ordered to manually release its locks via the module command *release-locks*. This is useful for manually changing the primary monitor. After running the release-command, the monitor will not attempt to reacquire the locks for one minute, even if it wasn't the primary monitor to begin with. This command can cause the cluster to become temporarily unusable by MaxScale. Only use it when there is another monitor ready to claim the locks.

```
maxctrl call command mariadbmon release-locks MyMonitor1
```

<sub>*This page is licensed: CC BY-SA / Gnu FDL*</sub>

{% @marketo/form formId="4316" %}