Upgrading MariaDB MaxScale from 2.0 to 2.1

Upgrading MariaDB MaxScale from 2.0 to 2.1

This document describes particular issues to take into account when upgrading MariaDB MaxScale from version 2.0 to 2.1.

For more information about MariaDB MaxScale 2.1, please refer to the ChangeLog.

Installation

Before starting the upgrade, we strongly recommend you back up your current configuration file.

IPv6 Support

MaxScale 2.1.2 added support for IPv6 addresses. The default interface that listeners bind to was changed from the IPv4 address 0.0.0.0 to the IPv6 address ::. To bind to the old IPv4 address, add address=0.0.0.0 to the listener definition.

Persisted Configuration Files

Starting with MaxScale 2.1, any changes made with the newly added runtime configuration change will be persisted in a configuration file. These files are located in /var/lib/maxscale/maxscale.cnf.d/.

MaxScale Log Files

The name of the log file was changed from maxscaleN.log to maxscale.log. The default location for the log file is /var/log/maxscale/maxscale.log.

Rotating the log files will cause MaxScale to reopen the file instead of renaming them. This makes the MaxScale logging facility logrotate compatible.

ReadWriteSplit

The disable_sescmd_history option is now enabled by default. This means that slaves will not be recovered mid-session even if a replacement slave is available. To enable the legacy behavior, add the disable_sescmd_history=true parameter to the service definition.

Persistent Connections

The MariaDB session state is reset in MaxScale 2.1 for persistent connections. This means that any modifications to the session state (default database, user variable etc.) will not survive if the connection is put into the connection pool. For most users, this is the expected behavior.

User Data Cache

The location of the MariaDB user data cache was moved from /var/cache/maxscale/<Service> to /var/cache/maxscale/<Service>/<Listener>.

Galeramon Monitoring Algorithm

Galeramon will assign the master status only to the node which has a wsrep_local_index value of 0. This will guarantee consistent writes with multiple MaxScales but it also causes slower changes of the master node.

To enable the legacy behavior, add root_node_as_master=false to the Galera monitor configuration.

MaxAdmin Editing Mode

The default editing mode was changed from vim to emacs mode. To start maxadmin in the legacy mode, use the -i option.

Comments

Comments loading...
Content reproduced on this site is the property of its respective owners, and this content is not reviewed in advance by MariaDB. The views, information and opinions expressed by this content do not necessarily represent those of MariaDB or any other party.